PM1 level crossed threshold

The PM1 level crossed threshold trigger fires when the PM1 (particulate matter 1 micrometer or smaller) reading on one or more air quality sensors crosses a specific level. PM1 particles are ultrafine, small enough to pass deep into the lungs and even enter the bloodstream. Everyday activities like burning candles, cooking, and using a fireplace produce these tiny particles.

With this trigger, your air purifier switches on the second PM1 rises above your chosen limit, clearing the air before you even notice a difference. You also get the option to send a notification to your phone when candle smoke or cooking pushes ultrafine particles past a safe level, giving you peace of mind that the air your family breathes is being watched around the clock.

Using this trigger from the user interface

If you prefer building automations visually, Home Assistant walks you through this trigger step by step. You pick what to watch, tweak a few options, and save. No YAML knowledge required.

To use PM1 level crossed threshold in an automation:

  1. Go to Settings > Automations & scenes.
  2. Open an existing automation, or select Create automation > Create new automation.
  3. In the When section, select Add trigger.
  4. Select what you want to monitor. Under By target (see Targets), pick the area your PM1 sensor is in (like your living room or bedroom). You can also select a device, a specific entity, or a label.
  5. From the triggers shown for that target, select PM1 level crossed threshold.
  6. Under Threshold type, configure the zone the reading must enter for the trigger to fire:
    • Select Above or Below and enter a value to fire when the reading crosses that level.
    • Select In range and enter a lower and upper bound to fire when the reading enters the range from outside.
    • Select Outside range and enter a lower and upper bound to fire when the reading leaves the range (crosses past either bound).
    • For each option, you can enter a fixed level in μg/m³, pick a sensor entity or a number helper entity as the threshold.
      • If you don’t have a number helper, you can create one by selecting Create a new number helper.
  7. Under Trigger when (see Behavior), pick Each, First, or All to control how the trigger behaves when multiple entities are targeted.
  8. Under For at least, set how long the reading must stay past the threshold before the trigger fires. Leave it at zero to fire immediately.
  9. Select Save.

Options in the UI

Threshold type

Controls which threshold crossings fire the trigger:

  • Above (exclusive): fires when the reading crosses to strictly above the threshold. A reading equal to the threshold does not trigger a crossing.
  • Below (exclusive): fires when the reading crosses to strictly below the threshold. A reading equal to the threshold does not trigger a crossing.
  • In range (inclusive): fires when the reading crosses into the range. A reading equal to either bound is considered inside the range.
  • Outside range (exclusive): fires when the reading crosses out of the range. A reading equal to either bound is still considered inside the range.

For each mode you can enter a fixed level in μg/m³ or reference a sensor entity or a number helper entity.

Trigger when (Optional)

When multiple entities are targeted, controls when the trigger fires:

  • Each: fires every time any targeted entity crosses the threshold.
  • First: fires only on the first crossing.
  • All: fires only after every targeted entity crosses the threshold.

This corresponds to the behavior field in YAML. Default is Each.

For at least

How long the reading must remain past the threshold before the trigger fires. Useful to avoid triggering on brief fluctuations. For example, set it to 0:05:00 to fire only after the reading has stayed past the threshold for 5 minutes. Default is 0 (fires immediately).

Using this trigger in YAML

If you work directly in YAML, or you want to know exactly what Home Assistant does under the hood, this section has the technical reference. It lists the field names you use in YAML, their types, and which ones are required. For how an automation is built in YAML, refer to Automations in YAML.

In YAML, put the settings that are specific to this trigger under options. Keep target, if the trigger uses one, and general settings such as id, alias, enabled, and variables at the top level, next to trigger.

When this trigger starts an automation, it passes data about what happened to the automation. You can use this trigger data in the templates of your conditions and actions. To see which data is available, refer to Trigger data in templates.

In YAML, refer to this trigger as air_quality.pm1_crossed_threshold. A basic example looks like this:

TriggerA trigger is the part of an automation that makes the automation start when something specific happens, for example, when the sun sets, a door opens, or a button is pressed. [Learn more]
trigger: air_quality.pm1_crossed_threshold
target:
  entity_id: sensor.living_room_pm1
options:
  threshold:
    type: above
    value:
      number: 25

This fires when the living room PM1 sensor reading rises above 25 μg/m³.

Options in YAML

threshold map Required

A mapping that defines the threshold crossing that fires the trigger:

  • type: above (exclusive): Sets a minimum. Fires when the reading crosses to strictly above value. A reading equal to value does not trigger a crossing. Provide value with a number key (for a literal value in μg/m³) or an entity key (for an input_number, number, or sensor entity).
  • type: below (exclusive): Sets a maximum. Fires when the reading crosses to strictly below value. A reading equal to value does not trigger a crossing. Provide value with a number key (for a literal value in μg/m³) or an entity key (for an input_number, number, or sensor entity).
  • type: between (inclusive): Defines a range. Fires when the reading crosses into the range. A reading equal to either bound is inside the range. Provide value_min and value_max, each with a number key (for a literal value in μg/m³) or an entity key (for an input_number, number, or sensor entity).
  • type: outside (exclusive): Defines an outside-range. Fires when the reading crosses out of the range. A reading equal to either bound is still inside the range. Provide value_min and value_max, each with a number key (for a literal value in μg/m³) or an entity key (for an input_number, number, or sensor entity).

For example:

threshold:
  type: above
  value:
    number: 25
behavior string (Optional, default: each)

When multiple entities are targeted, controls when the trigger fires:

  • each (default): fires every time any targeted entity crosses the threshold.
  • first: fires only on the first threshold crossing.
  • all: fires only after every targeted entity crosses the threshold.
for string | integer | map (Optional, default: 00:00:00)

How long the reading must remain past the threshold before the trigger fires. Accepts a duration string in HH:MM:SS format. For example, 00:05:00 fires only after the reading has stayed past the threshold for 5 minutes. For a list of all accepted formats, refer to Durations in automations and scripts.

Targets of the trigger

This trigger requires a target. The target is the object that Home Assistant will watch. You can select a single entityAn entity represents a sensor, actor, or function in Home Assistant. Entities are used to monitor physical properties or to control other entities. An entity is usually part of a device or a service. [Learn more], a device, an area, a floor, or a label as a target, and Home Assistant will watch every matching PM1 sensor behind that target.

  • Entity: one specific PM1 sensor, such as sensor.living_room_pm1.
  • Device: every PM1 sensor that belongs to a device.
  • Area: every PM1 sensor in a room or area.
  • Floor: every PM1 sensor on a floor.
  • Label: every PM1 sensor that shares a label.

You can also select different target types in one trigger. For example, you can add a specific entity and an area as targets in the same trigger to monitor both of them at once.

To learn which entities Home Assistant includes for a device, area, floor, or label, and how it handles several entities, refer to Automation targets.

Trigger variables

When the trigger reacts, the trigger variable identifies the entity that made it react. This is useful when a target contains multiple entities, such as a device, area, floor, or label.

The following trigger-specific variables are available:

  • trigger.entity_id: Entity ID of the entity that made the trigger react.
  • trigger.from_state: Previous state object of that entity.
  • trigger.to_state: New state object of that entity.
  • trigger.for: Timedelta object of how long the trigger criteria were met, if applicable.

For example, use {{ trigger.to_state.name }} in an action to include the name of the entity that made the trigger react in a notification.

The trigger variable describes the entity that made the trigger react. It doesn’t contain all the entities of the target.

Behavior with multiple targets

When you target more than one entity (or select an area, floor, or label that contains several), the Trigger when option controls how the trigger responds:

  • Each (default): the trigger fires every time any one of the targeted entities transitions. For example, if you monitor three motion sensors in the living room and someone walks past sensor 1, the automation fires. When they walk past sensor 2 a moment later, it fires again. Every individual event counts.
  • First: the trigger fires only on the first transition in the targeted group, then waits until none of the targeted entities is in that state anymore before it fires again. For example, if you monitor the same three motion sensors, the automation fires when the first one picks up movement (someone entered the room). The other two firing afterward are ignored, so you get one notification per “someone walked in” event instead of three.
  • All: the trigger fires only after the last targeted entity in the group has fired, meaning all of them are now in the expected state. For example, if you monitor the lights in the living room, bedroom, and hallway, the automation fires only once all three have turned off. This is useful for scenarios like “start the robot vacuum only after every light on the floor is off,” so you know the room is truly empty.

Good to know

  • The threshold type sets the direction. With Above, the trigger fires when the level rises above the threshold. With Below, it fires when the level drops below it.
  • PM1 is one of the finest fractions of particulate matter. If your sensor also reports PM2.5 or PM10, you get a fuller picture of air quality by combining triggers for each size.
  • Pair this trigger with PM1 level changed if you want to react to every change of the level instead.
  • The threshold is in μg/m³. A sensor that reports PM1 in another unit never matches. If you use an entity as the threshold, it must also report μg/m³.

Try it yourself

Ready to test this? Go to Settings > Automations & scenes, create a new automation, and add this trigger. Save the automation, and then make the trigger react. For example, change the state of the targeted entityAn entity represents a sensor, actor, or function in Home Assistant. Entities are used to monitor physical properties or to control other entities. An entity is usually part of a device or a service. [Learn more], turn on a light that the trigger monitors, or change its brightness. To check whether the automation ran, open its traces.

More examples

Real scenarios where this trigger fires in automations and scripts. Copy any example and adapt it to your setup. In the visual editor, select the UI options listed in the example when they are available, or paste the YAML code.

Tip

You don’t need to edit YAML to use these examples. Copy a YAML snippet from this page, open the visual automation editor in Home Assistant, and press Ctrl+V (or Cmd+V on Mac). Home Assistant automatically converts the pasted YAML into the visual editor format, whether it’s a full automation, a single trigger, a condition, or an action.

Automation: start the air purifier when ultrafine particles rise

Candles, cooking, and fireplaces all release ultrafine particles that are invisible but still matter. This automation starts the living room air purifier the moment PM1 rises above 25 μg/m³, clearing the air before you notice a thing.

  • Trigger: PM1 level crossed threshold
  • Target: Living room PM1 sensor
  • Threshold type: Above 25 μg/m³
  • Trigger when: Each
  • Action: Turn on switch (air purifier)
YAML example for PM1-based air purifier
AutomationAutomations in Home Assistant allow you to automatically respond to things that happen in and around your home. [Learn more]
alias: "Air purifier on high PM1"
triggers:
  - trigger: air_quality.pm1_crossed_threshold
    target:
      entity_id: sensor.living_room_pm1
    options:
      threshold:
        type: above
        value:
          number: 25
actions:
  - action: switch.turn_on
    target:
      entity_id: switch.living_room_air_purifier

Still stuck?

To find out why the trigger didn’t react, make the change that it should react to, and then open the traces of the automation. If the automation didn’t run, there’s usually no trace, but some triggers record a Did not trigger trace. For details, refer to Testing automations. For common problems and their solutions, refer to Troubleshooting automations.

If that doesn’t help, the Home Assistant community is quick to help: join Discord for real-time chat, post on the community forum with the trigger you’re using and what you expected to happen, or share on our subreddit /r/homeassistant.

Tip

AI assistants like ChatGPT or Claude can also explain triggers or suggest the right one when you describe what you want in plain language.